logo
Good price  online

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Gas Detector
Created with Pixso.

Bag Filter Leak Detector Insertion Type Dust Analyzer Durable Electrode Design

Bag Filter Leak Detector Insertion Type Dust Analyzer Durable Electrode Design

Brand Name: JUGE
Model Number: None
MOQ: 1 Unit
Price: USD100-1000
Packaging Details: Neutral carton
Payment Terms: Online order, T/T
Detail Information
Place of Origin:
Nanjing, China
Certification:
IOS9001, CE
Name:
Bag Filter Leak Detector
‌Dust Particle Size Range‌:
Nominal 0.1μm–400μm (signals Outside This Range Are Detectable With Varying Characteristics)
‌Probe Structure‌:
400mm / 800mm (standard); 200mm, 600mm, 750mm, 1000mm (customizable)
‌Pipeline Gas Temperature‌:
≤260℃ / 400℃ / 800℃ (options)
‌Pipeline Gas Flow Velocity‌:
1m/s To 30m/s
‌Pipeline Gas Pressure‌:
-0.1 To 2MPa
‌Measurement Range‌:
0–50, 100, 200, 5000, 20,000 Mg/m³ (custom Ranges Available)
‌Transmitter Power Supply‌:
15–32VDC Or Configurable 220V Supply
Supply Ability:
100 Unit/Week
Highlight:

Bag Filter Leak Detector

,

Insertion type Dust Analyzer

,

Durable Electrode Leak Detector

Product Description
Bag Filter Leak Detector Insertion-type Dust Analyzer
 
>>Overview

The dust concentration analyzer adopts the world's advanced AC coupling technology, utilizing precise and reliable electrostatic measurement principles. When dust particles pass through the sensor, their weak charges are captured and transmitted to the processor. The processor converts these signals into output values linearly correlated with dust concentration, enabling real-time online monitoring. Widely applied in power generation, metallurgy, cement production, pharmaceuticals, chemicals, food processing, and other industries.

 
>>Features

Robust Structure:‌ Composed of a sensor unit and transmitter unit for high anti-interference performance.

Durable Electrode Design:‌ Special material coating ensures superior high-temperature resistance, corrosion resistance, and anti-adhesion capabilities.

Sealed Construction:‌ Optimized housing design with airtight connectors prevents gas leakage and protects electrodes from external impacts.

Automatic Zero Calibration:‌ Transmitter features self-zeroing to eliminate data drift.

Polarity-Free Power Supply:‌ Operates on non-polarized DC-24V, preventing equipment damage from wiring errors.

Efficient Leak Detection:‌ Replaces manual inspection and guides dust removal/emission control.

Linear Signal Output:‌ Two-wire system (4-20mA) ensures strong noise immunity and long-distance transmission.

No special cable requirements.

Current output linearly correlates with dust concentration for seamless PLC integration.

 

 

>>Main technical parameters

Operating Ambient Temperature

-20℃ to 60℃ (electronic components)

Operating Ambient Humidity

≤90% non-condensing

Operating Ambient Vibration

Maximum continuous vibration in any direction and frequency: RMS 2g (20m/s²)

Operating Ambient Electromagnetic Field

Maximum at 50 Hz = 60A/m (equivalent to a 50AT field in a 1m×1m square coil)

Operating Environmental Protection

Protection rating: IP65/NEMA4 (aluminum alloy housing, suitable for non-corrosive environments; stainless steel probe)

Pipeline Gas Pressure

-0.1 to 2MPa

Pipeline Gas Flow Velocity

1m/s to 30m/s

Pipeline Gas Temperature

≤260℃ / 400℃ / 800℃ (options)

Probe Structure

400mm / 800mm (standard); 200mm, 600mm, 750mm, 1000mm (customizable)

Dust Particle Size Range

Nominal 0.1μm–400μm (signals outside this range are detectable with varying characteristics).

Zero Drift

(Time) <1% of range annually.
(Temperature) <1% of range within specified temperature limits.

Full-Scale Drift

(Time) <1% of range annually.

Circuit Stability

All components use high-stability electronic assemblies.

Noise Immunity

All 50/60Hz noise and harmonics are filtered prior to signal reception.

Measurement Range

0–50, 100, 200, 5000, 20,000 mg/m³ (custom ranges available).

Transmitter Output

Two-wire 4-20mA; optional relay output; audible/visual alarm.

Transmitter Power Supply

15–32VDC or configurable 220V supply.