Brand Name: | JUGE |
Model Number: | AG-600-A8 |
MOQ: | 1 Unit |
Price: | USD1000-10000 |
Packaging Details: | Neutral carton |
Payment Terms: | Online order,T/T |
PM1.0 PM2.5 PM10 PM100 TSP Dust and Noise Online Monitoring System
>>Overview
Modular Design: Configurable with flexible combinations to customize monitoring factors as needed, suitable for large-scale grid deployment.
Self-Calibration: Features optically stable self-calibration and online zero-correction systems to eliminate long-term operational drift. Traceable to national standard stations.
Multi-Size Particle Monitoring: Measures PM₁.₀, PM₂.₅, PM₁₀, PM₁₀₀, and TSP simultaneously via metallic cutters without replacing sampling components.
Dynamic Humidity Control: Utilizes dynamic heating dehumidification with continuous humidity compensation to minimize environmental interference.
Robust Sampling System: Long-life, low-noise, anti-interference pump with adjustable sampling cycles.
Flexible Data Transmission: Integrated 4G/5G, RS485, and wireless units support data transfer via GPRS/CDMA, 3G/4G/5G networks, or dedicated lines. Enables 24/7/365 operation, remote parameter adjustment, and fault diagnosis.
Expandable Sensors: Optional modules for meteorological parameters (negative oxygen ions, rainfall, radiation, UV, etc.).
Intelligent Imaging: Configurable cameras with night vision and long-range capture capabilities; supports auto-snapshot, video overlay, and real-time viewing.
Particulate Matter (PM) | |
Measurement Method | Laser Scattering |
Measured Parameters | PM₂.₅, PM₁₀, PM₁₀₀, TSP |
Concentration Range | PM₂.₅: 0-1000 μg/m³; PM₁₀: 0-2000 μg/m³; TSP: 0-30 mg/m³ (customizable) |
Concentration Precision | 0.1 µg/m³ |
Concentration Accuracy | ±2.5% or ±10 μg/m³ (whichever is greater) |
Pump Flow Rate | 2.83 L/min; PID-controlled ±2.5%; Accuracy: ±2.5% F.S. |
Dehumidification | DHS (Dynamic Heating System) with dynamic humidity control |
Particle Size Range | 0.3–100 μm |
Gas Path Protection | Standard |
Temperature Control | Adjustable (10–60°C ±1°C) |
Noise Monitoring | |
Measurement Range | 30–130 dB(A) |
Response Time | 200 ms |
Resolution | 0.1 dB |
Accuracy | ±0.5% F.S. |
Environmental Parameters | |
Temperature | Range: -40°C to +70°C; Resolution: 0.1°C; Accuracy: ±0.2°C |
Humidity | Range: 0–100% RH; Resolution: 0.1% RH; Accuracy: ±3% RH |
Wind Speed | Range: 0–60 m/s; Resolution: 0.1 m/s; Accuracy: ±(0.3 + 0.03V) m/s |
Wind Direction | Range: 0–360°; Resolution: 1°; Accuracy: ±3° |
Atmospheric Pressure | Range: 45–120 kPa; Resolution: 0.01 kPa; Accuracy: ±0.05 kPa (25°C @ 103.5 kPa) |
Local Display | 4-line display; Switch power supply; RS485 interface; Dimensions: 1020×540×120 mm |
Mounting Setup | 3m national-standard pole (or bracket); Lightning rod (Ø89 mm, 2 mm thickness, two 1.5m threaded rods). Wall-mount optional. |
Data Transmission | 4G/5G/RS232/RS485; Compliant with Chinese national standard HJ 212-2017 |
Power Supply | AC 220V 50Hz; 150W; Protections: leakage/overload/surge |
Operating Environment | Temperature: -40°C to +70°C; Humidity: 0–95% RH (non-condensing); IP53 rating |
Host Functions | |
Data Capture Rate | ≥90% for particulate data |
Local Storage | ≥24 months of historical data |
Data Recovery | Auto-recovery and retransmission upon network restoration |
Linkage System | Supports mist cannon and spray linkage |
Remote Management | Remote firmware updates, parameter configuration, linkage control, and diagnostics |